MONKON stands out as a beacon of excellence in providing top-notch medical solutions. With a strong commitment to innovation and customer satisfaction, MONKON introduces the Movable Ventilator MKPV06, designed to revolutionize respiratory care delivery.
Unraveling the Movable Ventilator MKPV06
The Movable Ventilator MKPV06 is not just another ventilator; it’s a game-changer in the realm of respiratory therapy. Let’s delve into its features and functionalities:
1. Advanced Ventilation Modes
Ventilation modes are crucial for tailoring respiratory support to individual patient needs. The MKPV06 offers a comprehensive range of ventilation modes, including:
- VCV (Volume Control Ventilation)
- PCV (Pressure Control Ventilation)
- VSIMV (Volume Synchronized Intermittent Mandatory Ventilation)
- PSIMV (Pressure Synchronized Intermittent Mandatory Ventilation)
- PRVC (Pressure Regulated Volume Control)
- V+SIMV (PRVC + SIMV)
- CPAP/PSV (Continuous Positive Airway Pressure/Pressure Support Ventilation)
- BPAP (Bilevel Positive Airway Pressure)
- APRV (Airway Pressure Release Ventilation)
These modes ensure precise control over tidal volumes, pressures, and respiratory rates, facilitating tailored therapy for patients with diverse respiratory conditions.
2. Oxygen Therapy Integration
Ensuring adequate oxygenation is paramount in critical care settings. The Movable Ventilator MKPV06 seamlessly integrates oxygen therapy options, providing clinicians with the flexibility to optimize oxygen delivery based on patient requirements.
3. Comprehensive Monitoring Capabilities
Effective patient monitoring is essential for assessing treatment efficacy and ensuring patient safety. The MKPV06 offers a range of monitoring features, including:
- Waveform display
- Numeric data presentation
- Loop display
- Trend analysis
These monitoring capabilities empower clinicians with real-time insights into patient respiratory status, facilitating prompt intervention when necessary.
4. Intelligent Control Settings
The MKPV06 boasts a plethora of control settings, allowing clinicians to fine-tune ventilation parameters with precision. From adjusting tidal volumes to setting inspiratory and expiratory pressures, the ventilator offers unprecedented control over ventilation dynamics.
Technical Specifications
Let’s explore the technical specifications of the Movable Ventilator MKPV06:
Parameter | Specification |
---|
Dimensions (LWH) | 380 mm * 325 mm * 675 mm |
Weight | Approximately 14.9 kg |
Screen | 12.1 TFT color touch screen |
Resolution | 1280*800 |
Ventilation Modes | VCV, PCV, VSIMV, PSIMV, PRVC, V+SIMV, CPAP/PSV, BPAP, APRV |
Oxygen Therapy | Available |
Monitoring | Waveform, Numeric, Loop, Trend |
Control Settings | Customizable |
Packaging & Delivery
- Packaging: Standard export package
- Delivery: Within 7-10 workdays after receipt of payment
Environmental Specifications
Parameter | Specification |
---|
Temperature | 5-40°C |
Relative Humidity | 10-95% |
Barometric Pressure | 62-106kPa |
Communication Interface
The MKPV06 features multiple communication interfaces, including HDMI, RS232, USB, Nurse call, CO module connector, and SPO module connector, ensuring seamless integration with existing hospital infrastructure.
Value Added Functions
Function | Specification |
---|
Suction | Available |
Nebulization | Available |
Manual Breath | Available |
Inspiratory Hold | Available |
Expiratory Hold | Available |
PEEPI | Available |
P0.1 | Available |
NIF | Available |
PV Tool | Available |
Physical Characteristics
Parameter | Specification |
---|
Dimensions | 380 mm * 325 mm * 675 mm |
Weight | Approximately 14.9 kg |
Screen | Size: 12.1 TFT color touch screen |
| Resolution: 1280*800 |
Movable Ventilator MKPV06 embodies excellence in respiratory care technology. With its advanced features, customizable settings, and robust construction, it serves as a testament to MONKON’s commitment to innovation and quality in the medical supply chain industry.
FAQs (Frequently Asked Questions)
- Is the Movable Ventilator MKPV06 suitable for both adult and pediatric patients?
- Yes, the ventilator offers customizable settings for both adult and pediatric ventilation requirements.
- Does the MKPV06 support non-invasive ventilation (NIV)?
- Absolutely, the ventilator includes NIV capabilities to cater to a wide range of patient needs.
- Can the MKPV06 be integrated into existing hospital communication systems?
- Certainly, the ventilator features multiple communication interfaces for seamless integration with hospital infrastructure.
- What warranty does MONKON offer for the Movable Ventilator MKPV06?
- MONKON provides a one-year hardware warranty for the MKPV06, ensuring peace of mind for customers.
- Is technical support available for the installation and operation of the MKPV06?
- Yes, MONKON offers comprehensive technical support to assist customers with installation, training, and troubleshooting of the ventilator.
With the Movable Ventilator MKPV06, MONKON continues to set the standard for excellence in respiratory care, empowering healthcare providers worldwide to deliver superior patient outcomes.