MKCTX10 by MONKON stands tall as a beacon of innovation and precision. Designed to deliver unparalleled diagnostic insights, this state-of-the-art system embodies the fusion of advanced technology and medical expertise. Let’s delve into the intricacies of this groundbreaking device and explore how it’s shaping the landscape of modern healthcare.
Marvel: Precision 32 Computed Tomograph System MKCTX10
At the heart of medical diagnostics lies the need for accuracy and clarity, and the Precision 32 Computed Tomograph System MKCTX10 exceeds these expectations with its revolutionary features. From its AccuScan technology, which ensures precise imaging with minimal radiation exposure, to its Ahead-Head dual-energy head imaging technology, every aspect is meticulously crafted to elevate diagnostic capabilities.
AccuScan: Redefining Precision
AccuScan isn’t just a feature; it’s a testament to MONKON’s commitment to precision and patient safety. By optimizing scan parameters based on individual patient characteristics, AccuScan minimizes radiation dosage without compromising image quality. This not only enhances diagnostic accuracy but also underscores MONKON’s dedication to patient-centric healthcare solutions.
AccuTilt: The Art of Flexibility
Gone are the days of rigid imaging setups. With AccuTilt dual-mode gantry tilt technology, the Precision 32 Computed Tomograph System MKCTX10 offers unprecedented flexibility. Whether it’s adjusting gantry tilt for optimal imaging or accommodating patients with mobility constraints, AccuTilt ensures adaptability without sacrificing image integrity.
AccuOrgan: Targeted Precision, Amplified
When it comes to organ-specific imaging, precision is paramount. AccuOrgan harnesses advanced algorithms to tailor imaging parameters to specific anatomical structures, delivering unparalleled clarity and detail. From cardiac assessments to neuroimaging, AccuOrgan empowers clinicians with the insights needed for informed decision-making.
Admir: Iterating Towards Excellence
In the pursuit of diagnostic perfection, iterative reconstruction plays a pivotal role. Admir iterative reconstruction technology employed in the Precision 32 Computed Tomograph System MKCTX10 refines raw data into clinically relevant images with remarkable clarity. This not only enhances diagnostic confidence but also reduces imaging artifacts, ensuring an unobstructed view of pathology.
AccuDose: Redefining Low-Dose Imaging
With concerns over radiation exposure looming large, AccuDose emerges as a beacon of hope. By optimizing imaging protocols and leveraging cutting-edge dose modulation techniques, AccuDose enables comprehensive low-dose imaging without compromising diagnostic quality. This not only safeguards patient well-being but also underscores MONKON’s commitment to responsible imaging practices.
Technical Specifications: Delving into the Details
Feature | Specification |
---|
Slip ring | Germany low-voltage slip ring |
Aperture Size | 715±5mm |
Tilt Angulation Range | -30° ~ +30° |
Scan localizer | Positioning laser |
Slice Thickness | 2×1.1mm, 8×0.55mm, 16×0.55mm, 16×1.1mm |
Scan time (s/360°) | 0.72s, 0.8s, 1.0s, 1.5s, 2.0s |
Maximum FOV | 500mm |
Detector Type | GOS ceramic solid detector |
Detector Number | 888×24 |
Detector Row | 24 |
Detector channel per row | 888 |
X-ray Tube | Varex GS-30719 |
Focal Spot Size | 0.7×0.8; 1.2×1.4 |
Cooling Method | Oil |
Heat Storage Capacity | 3.5 MHU |
Maximum Anode Cooling Rate | 8750W (12250 HU/sec) |
Maximum Continuous Anode Heat Dissipation | 3400W (4760HU/sec) |
High Voltage Generator | Spellman CT70PN42X5245 |
Maximum Power | 42kW |
Output Voltage | 60kV, 70kV, 80kV, 100kV, 120kV, 140kV |
Output Current | 10mA ~ 350mA |
Maximum Continuous Exposure Time | 100s |
Patient Couch | |
Movement Range | 0 ~ 1725mm |
Maximum Scan Range | 1650mm |
Horizontal Speed Range | 0.5 ~ 300mm/s |
Vertical Range | 450mm ~ 920mm |
Maximum Load Capacity | 205kg |
Console (Minimum Configuration Requirement) | |
CPU | 3.5GHz |
Hard Drive | 3TB |
Host Memory | 16GB |
Image Storage | 500GB |
Graphics | 3G |
Display Monitor | LCD 23’ LCD 1920×1080 Resolution |
Archive | DVDRW |
UPS for console | Configuration |
Axial Scan | |
Scan FOV | 500mm |
Recon FOV | ≥50mm and ≤500mm |
Recon Matrix | 512×512, 768×768, 1024×1024 |
Helical Scan | |
Slice Thickness | 8×0.55mm, 16×0.55mm, 16×1.1mm |
Pitch | 0.51:1~1.5:1 |
Max. Continuous scan length | 1650mm |
Max. Continuous scan time | 100s |
Recon FOV | ≥50mm and ≤500mm |
Recon Matrix | 512×512, 768×768, 1024×1024 |
Packaging & Delivery
- Packaging detail: Standard export package
- Delivery detail: within 7-10 workdays after receipt of payment
Precision 32 Computed Tomograph System MKCTX10 stands as a testament to MONKON’s unwavering commitment to excellence. With its innovative features, meticulous craftsmanship, and unparalleled performance, it’s not just a device; it’s a beacon of hope for clinicians and patients alike. As we navigate the complexities of healthcare, let MONKON be your partner in precision, your ally in diagnosis, and your beacon of hope in the journey towards better health.
FAQs
- Is the Precision 32 Computed Tomograph System MKCTX10 suitable for pediatric imaging?
- Yes, the system is equipped with dose modulation techniques to ensure safe and accurate imaging for pediatric patients.